首页 About Us Products News Feedback Certificate Contact Us
  You are here: 500W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER  
 


500W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER

300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)

 

System Function                                             
Display function
1、 AC voltage display
When the 125VAC LED lit up, it means the AC output is 125V.
When the 230VAC LED lit up, it means the AC output is 230V.
2、 Outage display
When the Fault LED lit up, is means there is no electricity or the output is fail, and the inverter restart.
3、 Power shows
Power output LED: The 5 red LEDS take turns lighting, the quicker the lights move, the more power output.
4、 AC frequency display
When the 50Hz LED lit up, it means the input frequency is 50Hz.
When the 60Hz LED lit up, it means the input frequency is 60Hz.
5、 DC over-voltage display
When the Fault LED and the “HIGH” LED lit up, it means the DC input is over 62VDC
6、 DC under- voltage display
When the Fault LED and the “LOW” LED lit up, it means the DC input is low 22VDC.
7、 Power adjust display
1)      When “ST” LED flashing, it means power is in adjusting condition.
a.       When the “ST” LED and “HIGH” LED lit up, it means the power is increase.
b.       When the “ST” LED and “LOW” LED lit up, it means the power is decrease.
2) When “ST” LED long on time, is means the power is locked, and the inverter works.
6-grade power search
    In overcast weather, the solar battery’s output current is extremely tiny, then inverter will automatic open 6-grade power search function.
1、The program can automatically open power adjustment for 6 times.
2、The current direction can adjust from the maximum to the minimum.
3、In automatic adjustment process, we will see the LOW light flashing. And the power will keep as a starting point, from 0 to the maximum
output power, and it will restart at most for 6 times, then locked in the maximum power, the ST lamp long bright.
4、It need 10 minutes for 6-grade power search.
voltage input(22-60VDC
1、DC voltage input:22-60VDC
2、Second level power variable voltage conversion
High-frequency two-way and one-way grid function
1、 High frequency direct modulation, AC half wave synthesis
2、 Two-way grid means: Load consume directly. And can reverse AC current transmission.
3、 One-way grid means: Load consume directly. And banned reverse AC current transmission.
Kinds of frequency output function.
It can apply to 50Hz and 60Hz frequency of AC.
Frequency range: 45Hz ~53Hz/55Hz~ 63Hz
directly connected to the solar panels (do not need to connect the battery)
Using precise Dynamic differential pressure type MPPT function, APL functions, the inverter automatically adjust the solar panels of maximum
output power,simply connect the solar panel to the grid inverters. Do not need to connect the battery.
1、 Differential pressure type MPPT: 0.1 V accuracy
2、 Power lock: 10W (AC output)
AC 0 angle with high precision auto-detection
AC phase angle of 0 through isolation amplifier then input to the MCU for high-precision detection and analysis. The phase shift rate is less
than 1%, thus achieve high-precision with phase modulation AC output together.
1、 AC phase shift: < 1%
2、 Over-zero protection: 0.2 VAC
3、 AC switching: 50Hz / 60Hz
Synchronous High-frequency Modulation
In the process of the grid, usually adapt the same phase angle in parallel. (ie, When the two-phase alternating current total is equal to 0.Use
switch to combination the two AC fusion) and the product is rectified AC half-frequency AC to 100Hz first, then the machine use the high frequency
current in the circuit and semi-100Hz frequency alternating current generated combination, to achieve high-frequency modulation.
1、 Modulation synthesis: half wave and full-bridge modulation synthesis (100Hz / 120Hz)
2、 Synthetic way: MOSFET full-bridge
3、 High frequency: 50KHz
Pure Sine Wave Output
Use SPWM directly to make pure sine wave output.
1、Output waveform: Adopt complementary PWM to push-pull pure sine wave.
2、Generate means: enhancement-mode SPWM
Automatic Sensing Function Solar Luminosity
Use the latest luminosity perception operation technology. The different illuminate angle and intensity of the solar panel will produce different
current output. Use advanced CPU to operate the different illuminance and the data can be directly displayed on the LCD. Then you can visually
see the sense of the strength of the sun unit. Used more convenient.
1、 Luminosity sampling point power sampling point
2、 High precision AD sampling: integral AD sampling method
Power Automatically Locked (APL)
In different current fluctuations, we should use the MPPT function. When the MPPT function adjusted to the maximum power point, the product
automatically powers locked in maximum power point, then made the output power more stable.
1Power lock: The biggest sampling point of MPPT.
Automatically Adapt To Different Load Power Factor
Adapt to any of the power load.
Constant Current, Constant Power
This product is constant current, constant output power, without any overload, over-current phenomenon.
Automatically Shut Down When The Power Output Of a Fault
When the city power system is in failure, the inverter will automatically turn off the output.
Current Limit Protection
Current limit
Stack Multiple Machines
l         Multiple small power inverters in parallel can achieve large output power.
High-Frequency High Conversion Rate
Adapt high frequency converter, the output more efficient.
Maximum Power Point Tracking (MPPT)
Because the current intensity and the voltage changes at any time, if there is no power point tracking, there will be a lot of problems. In the
past time, usually adopt a solar controller, but this product uses high-precision     MPPT operation power, automatic and immediate adjust
the solar panels output power at the maximum output point, then achieve a stable output purposes.
MPPT is for short of "Maximum Power Point Tracking". It means the controller can sense the voltage of the solar panels on time, and can track
the highest voltage and current (VI).Then made the inverter discharge to power grid with the highest efficiency.
The peak voltage (Vpp) of the solar panels is about 19.5V when it in factory. And the environment temperature is 25 ° C. The reason of setting
this temperature(interestingly, different from the subjective imagination, we ordinary people the conclusion may let us surprised) is that when
the weather is very hot, solar panels’ peak voltage will fall to about 17.5 V while in cold weather, the peak voltage can achieve 20.8 V.
Now we back to contrast the difference of MPPT solar energy grid inverter and traditional inverter. The traditional solar inverter is a bit like the
manual gearbox. When the engine speed increase, while the gearbox gear don't increase at the same time, it will definitely affect the speed
of the car. For traditional inverter speaking, the parameter output power is been set in factory. It likes a car have been fixed set on fixed 1 gears,
no matter how powerfully you trample accelerator, the speed of a car is limited. While have the MPPT function it will be different, it is automatically.
It will automatically adjust the gears according to the engine’ speed, so it can make cars in the most gears in a reasonable efficiency standard
operation. It means the MPPT controller can track the maximum power point of solar panels in real-time then express the biggest efficiency of
solar panels. The higher the voltage, the more power can be output through the MPPT. Thus improve the charging efficiency. Theoretically speaking,
using MPPT, the efficiency can be increased by 50% compared with the traditional inverter. But due to environmental impact and various around
energy loss, the ultimate efficiency can improve 20%-30% according to our actual testing.
 
INPUT 22-60VDC GRID TIE SOLAR INVERTER SP-WV 300W-500W PARAMETER TABLE:

300Watt
500Watt
Recommend use solar panels
400Wp
600Wp
DC MAX input current
20A
40A
AC MAX output power
300Watt
500Watt
DCMAX Open-circuit input-voltage
100VDC
DC input voltage range
22~60VDC
MAX output power factor
0.99
DC input Reverse voltage protection
FUSE
AC output voltage range
(120V versions: 90~140VAC)(230V versions: 180~260VAC)
AC frequency range
45-53Hz/55-63Hz
Output current total
harmonic distortion
THDIAC <5%
AC Phase
<0.5%
Islanding protection
VAC; f AC
Output short circuit protection
Current-limiting
Show
LED mode: power instruction; voltage instruction; AC frequency instruction; over-voltage instruction
Installation
Wall hanging
Cooling
Fan
Communication way
60KHz modulationpower line carrier-current communication
Standby Power
<1W
Night Power
<1W
Ambient temperature range
-25 ~60
Humidity
0~99%(Indoor Type Design)
Waterproof
Indoor Type Design
Electromagnetic Compatibility
EN50081.part1   EN50082.part1
Power System Disturbance
EN61000-3-2 EN60950-1
Network test
DIN VDE 1026

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Packing and weight                                                 

N.W(Each inverter)
1.3KG(300W/500W)
G.W(Each inverter)
1.8KG(300W/500W)
Each inverter size (L x W x H)
21 x 16.5 x5.3CM
Inner carton size(L x W x H)
30.5x21x11.5CM(1PC)
Master carton size(L x W x H) 
43x32x38CM (6 PCS)
N.W(Outer packing)
11KG(300W/500W )
G.W(Outer packing)
12KG(300W/500W )

 
 
 
 
 
 
 
  
 
Installation instruction   
 
300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)                                               
Figure 1
 
 1Please read the below notes carefully before installation.
A) Make sure the open voltage and operation voltage is in the range of 22-60V, and we recommend the 36V rated voltage solar panel.
B) Make sure the inverter’s AC voltage and frequency is the same with power grid voltage and frequency.
C)Installation inverter in the low humidity and well-ventilated place to avoid the inverter damp and overheating, And clear the inflammable and
explosive materials around.
E)Recommended to use 4AWG DC input cable that can handle more than 50A current.
F)DC input cable no more than 8M, because long DC cable will reduce the voltage from solar panel to inverter, then make some loss.
G)There must be a circuit breaker between solar power generation and power grid(show like the “control switch” in figure 1). And there will
be no load before the circuit breaker.
H)Before connect all the connections, you must disconnect the utility power. After make sure the all connections are right then connect the utility
power.
I)If you need to disconnect the mains switch when the solar power generation is in operation, you must disconnect the control switch first(show
like the “control switch” in figure 1).
J)Avoid children touch or play the inverters, in order to prevent electric shock.
K)Non-professional do not disassemble the inverter, only qualified serviceman can repair it.
 
2Connection DC terminal
Connect the solar panels positive terminal to inverter’s positive terminal, and negative to negative. And you must screw up the nut to avoid the
bad contact. Show in figure 2:300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)
Figure 2
 
3Connection of AC terminal
Before connect the inverter’s AC cable to the socket, you must disconnect the utility power. Then put the AC cable which has holes terminal into
the inverter’s 3 feet port and the pin terminal to the socket. Please make sure both of the terminal are connect fastness to avoid bad contact.
Show like figure 3:300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)   Figure 3
                                    
4Operation
After all connection, first open the mains switch, then open the inverter. When the inverter’s green LED shows, it means the inverter start to work.
 
5Several or many inverters used in parallel.
In order to achieve higher power, we can use this inverter in stack. For example: 4 pcs of 300W grid tie inverter used in stack can achieve 1200W.
And the stacking number is unlimited. Show like figure 4: 
 300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)
                                     Figure 4
6. Single-phase connection
Connection electrical diagram of the solar inverter used in single-phase power generation system, show b
300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)
 300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)
 7. Three-phase connection
Connection electrical diagram of the micro inverter used in three-phase generation system, show below:
  300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)
300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)
300W INPUT 22-60VDC WIDE VOLT GRID TIE INVERTER (SP-WV-300)
Accessories for product                                                         
One standard AC wire
One user manual

 

 

 
Copyright© Yueqing Supower Electric Co., Ltd. Sitemap Directly buy SUPOWER inverter from http://www.aliexpress.com/store/410860